Sign In | Join Free | My spintoband.com
spintoband.com
Kingsine Electric Automation Co., Ltd.
Kingsine Electric Automation Co., Ltd. Specialize in Electric Power Testing
Home > Relay Test Set >

Universal Relay Test Set Complied IEC61850

Kingsine Electric Automation Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment

Universal Relay Test Set Complied IEC61850

Place of Origin : China
Brand Name : Kingsine
Model Number : K3163i
Certification : ISO9001,CE
MOQ : 1 set
Delivery Time : 15 working days
Payment Terms : T/T in advance ,L/C
Supply Ability : 50 sets/ month
Analog signal channels : 6X30A,4X300V
Contact Now

Product Feature

Suitable testing for all kinds of Electromagnetics relays, Microcomputer relays; complete compling IEC61850/IEC60044-7/8 protocols, Facility for Merge Unit, and Numerical IED relays test.


100Mbit fiber ports, 10/100/1000Mbit Ethernet transfer multi-groups SMV and GOOSE, each SMV ability configure up to 64 sampling channels.


Able for subscriptions & simulations GOOSE, SMV messages signal.


Facility import/export/download/save Substation Configuration Language files (SCD/ICD/CID/NPI format files).


Simulate abnormal network fault conditions (Loss frame, mis-ordering, quality abnormal, message resend, data unusual, synchronism etc).


13 low-level signal outputs for low-level protection relay testing.


Facility for energy meter and transducer calibrate.


AC/DC measurement, 0~600V, 0~5A.


Facility for pulse count.


Technical Parameters

Analog Generators

Current

AC 6X30A @ 450VA

AC 3X60A @ 850VA

AC 1X100A @ 1000VA

DC 6X20A @ 300W

Current Accuracy

<0.05%rd+0.02%rg,typ

<0.15%rd+0.05%rg,Guar

Voltage

AC 4X300V L-N @ 120VA Max

AC 2X600V L-L @ 240VA Max

DC 3X300V @ 120W

Voltage Accuracy

<0.07%rd+0.03%rg.guar. @ 0~300V

<0.03%rd+0.01%rg.typ. @ 0~300v

Distortion

<0.1%guar.(<0.05%typ)

Auxiliary DC:

0~300V @ 120W Max

0.5%rg guar

13 Low-level outputs

Quantity

13channels,Aviation connector

Output Power

AC 0~8Vrms,DC 0~10v

Current

Rating 2Ma, 10mA transient max.

Power

≥0.5VA

Accuracy

<0.2%(0.01~0.8Vrms)

<0.1%(0.8~8Vrms)

Resolution

250Uv

Distortion (THD %)

<0.1%guar.(<0.05%typ)

IEC61850 Fiber & GOOSE Ethernet Ports

Mode 1

1X100Base-FX Full Duplex,LC type

Mode 2

1XEthernet,10/100/1000Mbit,RJ45 type

Resolution

0.001Hz

Fiber Type

62.5/125um(Multiple optical fiber, Orange Red)

Wavelength

1310nm

Transmit distance

>1km

Indicator

SPD Green(light):valid connection

Link/Act Yellow(blinking):Data exchanging

Note

All hardware ready for activate

Frequency & Phase angle

Frequency Range

DC~1KHz,3KHz transient

Frequency Accuracy

±1ppm

Frequency Resolution

0.001Hz

Phase Angle

-360~+360°

Phase Accuracy

<0.05°typ,<0.1°Guar,50/60Hz

Phase Resolution

0.001°

Binary Input

Quantity

8pairs

Type

Wet/dry, pulse count, measurement

Threshold

0~600Vdc or potential free,Programable

Sample Rate

10KHz

Time Resolution

100us

Debounce Time

0~25ms(Software Controlled)

Time Range

Infinite

Time Errors

±1ms @ 0.001~1s

±0.1% @ >1s

Galvanic Isolation

4 isolated with each 2pairs

Input Impedance

600KΩ

Binary Outputs(Relay Type)

Quantity

4 pairs

Type

Potential free relay contacts, software controlled

Break capacity AC

Vmax:400Vac/Imax:8A/Pmax:2500VA

Break capacity DC

Vmax:300Vdc/Imax:5A/Pmax:150W

Binary outputs(Hi-speed Semiconductor)

Quantity

4 pairs semiconductor

Type

Open-collector, Aviation connector

Break capacity DC

Vmax:350Vdc

Ac(p-p)/Imax:0.5A/Pmax:150W

Response time

100us

AC/DC Measurement

Voltage Range

0~600Vrms(Rg:0.1V,0.6V,6V,60V,600V)

Voltage Accuracy

<0.1%rg

Current Range

0~5Arms(clamp input)

Current Accuracy

<0.1%rg

Frequency Range

45~65Hz,Accuracy <0.01Hz

Phase Accuracy

0~360°,<0.2°typ

Harmonic

2~20times,<0.5%rg

Transducer Calibration

DC Current

Range

DC: 0~±1Ma;1~±20Ma;Auto range

Max.input

600mA

Input Impedance

15Ω

Accuracy

<0.02%rg typ <0.05%rg Guar

DC Voltage

Range

DC 0~±10V

Max.input

±11V

Input Impedance

1MΩ

Accuracy

<0.02%rg typ <0.05%rg Guar

Energy Meter Calibration

Sensor Usage

Mechanical meters/Electronic meters

Sensor Output

High level:≥4.5V Low level:≤0.2V

Accuracy

<0.05% RG

Pulse Input

1 pulse input ports

Pulse Range

500KHz pulse input max

Pulse Output

1 transistor outputs

Size & Weight

PC Connection

1X10/100/1000M Base-Tx RJ45 Ethernet

Synchronizer port

IRIG-B,GPS SMA Antenna,IEEE1588

Others

RS-232

Aviation connector for pulse I/O and Binary output

Size

460X150X380mm

Weight

<19kg

Power Supply & Environment

Nominal input voltage

220Vac

Permissible input

100~264Vac

Nominal frequency

50/60Hz

Permissible frequency

45~65Hz

Power Consumption

1500VA max

Temperature(Operating)

0~ 55℃

Temperature(Storage)

-20~70℃

Humidity

5%-95%RH,non-condensing


Product Tags:

protective relay testing

      

Protection Relay Test Set

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

Universal Relay Test Set Complied IEC61850 Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: Kingsine Electric Automation Co., Ltd.
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0